• DE - German (International)
  • US - English (USA)
  • ES - Spanish (Spain)
  • IT - Italian (Italy)
  • SV - Swedish (Sweden)
  • FR - French (France)
  • UK - English (United Kingdom)
  • PT - Portuguese (Brazil)
  • ZH - Chinese (China)
  • NL - Dutch (Netherlands)
  • FI - Finnish (Finland)
  • IN - English (India)
  • RU - Russian
  • LinkCalendar
  • customLINK
  • LinkedIn
  • VuMedi
  • YouTube
Logo
Logo
  • FOR THE PHYSICIAN
    • Overview
    • Products
      • Product Filter
      • Hip
      • Knee
      • Limb Salvage
      • Upper Extremity
      • customLINK
      • Foot
      • Hand
    • Media Library
      • Overview
      • Registration
      • General Information for Use
      • customLINK
      • LINK Case Reports
      • Cleaning Instructions & Templates
      • ISO Certificates
    • directLINK
      • Current Issue
      • Archive
    • LINKademy Calendar
  • FOR THE PATIENT
    • Patient information for Implants
  • LINKademy
    • LINKademy.TV
    • Global Sales Education Channel
    • LINKademy Calendar
    • About LINKademy
  • ABOUT LINK
    • TRUST. INNOVATION. PROGRESS.
    • TRUST in partnerships.
    • INNOVATION with quality.
    • PROGRESS to perfection.
    • News
    • Code of Conduct
  • CAREERS
    • Overview
    • LINK as Employer
    • Traineeships at LINK
    • Job offers
  • CONTACT
    • Overview
    • LINK Newsletter
    • Contact Form
    • Locations
    • International Representatives
    • Legal Notice
  • Home page
  • FOR THE PHYSICIAN
  • Products
  • Product Filter

Product Filter

LINK Endo-Model

  • Highlights
  • Read more
  • LINK Endo-Model Standard
  • LINK Endo-Model - M
  • LINK Endo-Model - W*
  • Surgical Technique
  • Endo-Model celebrates 40 years
  • 3D view
  • Downloads
  • Sources
  • Successfully used for over 40 years1
     
  • Efficient driven by motion2
     
  • Reliable solution3, 4, 5

The Endo-Model is an implant with intrinsic stability.1, 5, 12 The various options (Endo-Model Standard, Endo-Model Modular, Endo-Model SL, Endo-Model W) offer a high degree of flexibility.

The Endo-Model has been used successfully for over 30 years now, and can boast an unparalleled clinical history with excellent clinical results.1, 2, 5, 8 Even after 15 years, the Endo-Model has a survival rate of 98.5%.9

The Endo-Model enables speedy and uncomplicated implantation, while the design of the implant ensures good postoperative function.10, 11 Its excellent kinematics mean that the Endo-Model gives a high level of stability, especially in extension.3, 11 The implant allows flexion of the joint up to 142° and hyperextension of 2°.

 

The LINK Endo-Model has been in use for over 30 years as a rotational or hinge knee prosthesis for both primary and revision arthroplasties. The Endo-Model Rotational Knee Prosthesis gives you a multiplicity of options.
The method for implanting the Endo-Model is simple and uncomplicated.2, 6 The prosthesis has an intracondylar and an intramedullary fixation, which provide a high degree of stability and protection against bacteria.1, 7 For patients with a hypersensitivity to metal, LINK also offers a special surface coating (LINK PorEx).13
 

Sizes:
4 different sizes for femoral and tibial components, for right and left in each case (XS, S, M, L).


Material:
CoCrMo, UHMWPE and LINK PorEx


Mechanism:
Available in rotational and hinge versions.


Type of fixation:
Cemented


Centralizers:
The shape of the centralizers enables a central position in the medullary canal. Furthermore, the centralizers prevent contact between the metal stem and the cortical bone, thus reducing stress peaks in the bone when bending forces are acting.3


LINK PorEx Technology:
For metal-sensitive patients, LINK offers a surface modification.13

Centralizers:
The shape of the centralizers enables a central position in the medullary canal. Furthermore, the centralizers prevent contact between the metal stem and the cortical bone, thus also preventing stress peaks in the bone when bending forces are acting.3


LINK PorEx Technology:
The implant is also available with a coating for metal-sensitive patients.13

The modular intracondylar total knee prosthesis, Endo-Model – M, is an addition to the Endo-Model Standard Knee Prosthesis.

Sizes:
4 different sizes for femoral and tibial components, for right and left in each case (XS, S, M, L).


Stem sizes:
Modular stem, cemented (EndoDur-S, LINK PorEx*): 50 mm-280 mm
Modular stem, cementless, tapered (Tilastan-S): 50 mm-280 mm
Modular stem, cementless, cylindrical (Tilastan-S): 60 mm (Ø 10-18 mm), 120 mm-280 mm (each size available in the following diameters: Ø 12-18 mm)


Mechanism:
Available in rotational and hinge versions.


Type of fixation:
Cemented and cementless

LINK MEGASYSTEM-C - Modular joint pairings, Endo-Model with female taper. Total condyle replacement and intracondylar versions.

The modular intracondylar total knee prosthesis, Endo-Model – W, is an addition to the Endo-Model Knee Prosthesis.

Sizes:
3 different sizes for femoral and tibial components, for right and left in each case (S, M, L).


Stem sizes:
Modular stem, cemented (CoCrMo): 100 mm-160 mm (Ø 12-16 mm)
Modular stem, cementless (Tilastan): 100 mm-160 mm (Ø 12-24 mm)


Material:
CoCrMo, UHMWPE and LINK PorEx**



Mechanism:
Available in a rotational version.


Type of fixation:
Cemented and cementless


Centralizers:
The shape of the centralizers enables a central position in the medullary canal. Furthermore, the centralizers prevent contact between the metal stem and the cortical bone, thus also preventing stress peaks in the bone when bending forces are acting.3


Compatibility:
The Endo-Model-W is compatible with the MEGASYSTEM-C. All the stems from the MEGASYSTEM-C which have a male taper can be used.
The high degree of modularity of this system allows both, partial bone replacement in the proximal and distal femur regions in small increments and also total femur replacement.
You can find further information under MEGASYSTEM-C.


*Internal designation
**Only custom-made

Endo-Model Standard

Endo-Model - New Coupling Mechanism V02

Name: 711_Endo-Model_Coupling_V02_Flyer_en_2016-02_001.pdf
Size: 555 KB

Endo-Model - Impl. Instr.

Name: 711_Endo-Modell_Impl_Instr_en_2023-01_009.pdf
Size: 3 MB

Endo-Model - OP

Name: 711_Endo-Model_OP_en_2023-01_008.pdf
Size: 3 MB

Endo-Model Knee Systems Bushing Exchange - Surgical Technique

Name: 712_Endo-Model_Buchsenwechsel_OP_Impl_Instr_en_2022-11_003.pdf
Size: 4 MB

Endo-Model MIRETO

Endo-Model MIRETO - Impl. Instr.

Name: 719_Endo-Model_Standard-M_MIRETO_Impl_Instr_en_2022-11_008.pdf
Size: 4 MB

Endo-Model MIRETO - OP

Name: 719_MIRETO_OP_RevisionOP_en_2020-09_007.pdf
Size: 4 MB

Endo-Model - M

Endo-Model – M - Impl. & Instr.

Name: 718_Endo-Model-M_Impl_Instr_en_2022-11_011.pdf
Size: 4 MB

Endo-Model M - OP

Name: 718_Endo-Model-M_OP_en_2020-02_006.pdf
Size: 3 MB

Endo-Model Other

710_Endo-Model_Teaserflyer_en_2019-08_002.pdf

Name: 710_Endo-Model_Teaserflyer_en_2019-08_002.pdf
Size: 2 MB

Endo-Model - Literature Research

Name: 711_Endo-Model_Literature_en_2019-09_003.pdf
Size: 3 MB

Endo-Model - Product Rationale

Name: 710_Endo-Model_Knee_System_Product_en_2020-12_001.pdf
Size: 4 MB
  1. Petrou et al., Medium-term results with primary cemented rotating-hinge total knee replacement - A 7- to 15- year follow-up, THE JOURNAL OF BONE & JOINT SURGERY (Br), 2004
  2. Nieder et al., Mid-term results of 1837 cases at Primary Knee Arthroplasty Follow-up period 2-12 years (mean 6.6 years), Scientific Exhibition: 20th SCIOT World Congress, 1996
  3. Engelbrecht et al., Die Rotationsendoprothese des Kniegelenks, Springer Verlag,1984
  4. Bistolfi et al., Endo-Model® Rotating-hinge Total Knee for Revision Total Knee Arthroplasty, Orthopedics, 2013
  5. Sanguineti et al., Total knee arthroplasty with rotating-hinge Endo-Model® prosthesis: clinical results in complex primary and revision surgery, Arch Orthop Trauma Surg, 2014
  6. Bistolfi et al., Results with the Endomodell rotating hinged knee prosthesis after 18 years of follow-up, University of Turin: Department of Orthopedics and Traumatology
  7. Lazano, Better Outcomes in Severe and Morbid Obese Patients (BMI>35kg/m^2) in Primary Endo-Model® Rotating-Hinge Total Knee Arthroplasty, The Scientific WorldJOURNAL, 2012
  8. Dae Kyung Bae et al, Long-Term Outcome of Total Knee Arthroplasty in Charcot Joint: A 10- to 22-Year Follow-u, THE JOURNAL OF Arthroplasty, 2009
  9. Mavrodontidis et al., Application of the Endomodel Rotating Hinge Knee Prosthesis for Knee Osteoarthritis, Journal of surgical orthopaedic advances, 2008
  10.  Argenson et al., Total knee arthroplasty in femorotibial instability, Orthopäde S45-47, 2000
  11. Atrey et al, A 3 year minimum follow up of Endoprosthetic replacement for distal femoral fractures - An alternative treatment option, Journal of Orthopaedics,2017
  12. Felli et al., The Endo-Model® rotating hinge for rheumatoid knees, Orthopäde, 2016.
  13. Bader et al. Alternative Werkstoffe und Lösungen in der Knieendoprothetik für Patienten mit Metallallergie, Der Orthopäde 2008

Waldemar Link GmbH & Co. KG

Joint Prostheses "Made in Germany"

Products

  • Hip
  • Knee
  • Limb Salvage
  • Upper Extremity

Company

  • LINKademy.TV
  • Careers
  • Contact

Your contact to us

Barkhausenweg 10
22339 Hamburg, Germany
Phone +49 (0)40-539 95-0
info@link-ortho.com

Standard Terms & Conditions (buying, selling) | Legal notice | Conditions of use | Privacy Policy | Privacy statement for job applicants

2023 © Waldemar Link GmbH & Co. KG

Please confirm

This area is intended exclusively for medical professionals and, in accordance with the German Advertising of Medicines Act (HWG), must only be made available to certain professional personnel.
No, I am not a medical professional

Login

User login

Enter your username and password here in order to log in on the website.
Register Reset Password